Switching system
1,slow-make switching element contact system.
2,momentary action switching element contact system.
acting as normally open or normally closed.the normally closed contact has forced opening.
Slow-make contacts with forced action are ideal for high switch ratings.
Up to three switching elements can be snapped to each actuator.
For the emergency-stop pushbutton and double pushbutton use the slow-make switching element.
Material
Material of contact:Gold-silver,silver-palladium ( for aggressive atmospheres ).
Switch housing:Polycarbonate(PC)
Mechanical characteristics
Terminals:Screw terminals;
Plug-in terminals 6.3*0.8mm;
wire cross-section 2*2.5mm2;
wire cross-section of stranded cable 2*1.5mm2;
For switches with plug-in terminals it is necessary to provide insulation sleeves and to maintain a spacing of 65mm between rows(mounting dimensions).
tightening torque:
Screws at the mounting flange max.25Ncm;
Screws at switching element max.50ncm;
Actuating force:
1 Normally closed 2N
1 Normally open 3.1N
Actuating travel:5.8mm±0.2mm;
Rebound time≤1ms;
Mechanical lifetime(with 1 switching element)
Pushbutton maintained action 1.5 million Cycles of operation;
Pushbutton momentary action 3million Cycles of operation;
Selector switch maintained action 1.25 million Cycles of operation;
Selector switch momentary action 2.5million cycles of operation;
Emergency-stop switch 50000 Cycles of operation;
Keylock switch maintained action 25000 Cycles of operation;
Keylock switch momentary action 50000 cycles of operation;
Electrical characteristics
The switches comply with the Standards for low-voltage switching devices EN IEC 60947-5-1;
Rated Insulation Voltage Ui500VAC/600VDC,as per EN IEC60947-5-1;
Contact resistance:New state ≤50mΩ as per DIN IEC 60512-2-4;
Isolation resistance:≥10mΩ between open contacts at 500 VDC,as per DIN IEC60512-2-10;
Electrical life:50000 cycles of operations;
Conventional free air thermal current 10A,as per EN IEC60947-5-1;
the maximum current in continuous operation and at ambient temperature must not exceed the quoted maximum values.
Switch rating
At switch rating AC for gold-silver and silver-palladium contacts,service category AC-15,as per EN IEC60947-5-1.
Voltage :230VAC, 400VAC, 500VAC
Current :7A,5A,4A
At switch rating DC for gold-silver contacts,service category DC-13,as per EN IEC60947-5-1;
Voltage :24VDC,60VDC,110VDC,250VDC;
Current:10A,5A,2.5A,0.6A;
Recommended minimum operational data Gold-silver contacts:
Voltage:24VDC ,110VDC
Current:10mA,2mA;
Protection class
Indicators and switches,fit for mounting into devices with protection and switches,fit for mounting into devices with protection class III.